CPAP, Auto CPAP and BiLevel

Viewed products

ResMed - AirCurve 10 VAuto BiLevel

The AUTO BILEVEL AirCurve 10 VAUTO by ResMed is the only Auto BiLevel existing on the market and the only one equipped with the BiLevel AutoRamp™ feature, which allows the device to replace the doctor in therapy control. It is also equipped with a patient's GSM automatic monitoring system, which communicates with the single AirView ResMed™ program to have a perfect check of the patient constantly updated and allows the possibility to send the data of the therapy to the treating physician.

The AutoRamp™ mode with the sleep detection principle is activated automatically providing a low pressure during the step of pre-sleep for greater comfort, gradually increasing the pressure until reaching the prescribed therapy from the time when the patient falls asleep.

The EasyBreathe™ algorithm allows a greater pressure support to easily treat patients with difficult conditions of obstructive sleep apnea, replicating the shape of the patient's breathing curve itself.

When the device is integrated into a humidifier and the heated ClimateLineAir™ circuit becomes able to provide the temperature and the optimum moisture content for the user, so as to obtain the maximum possible comfort by therapy. 

Caution: the package does NOT include the humidifier. 

The product is registered in Italy.
Use outside the Italian territory is under the full responsibility of the purchaser, knowing that the device is perfectly functional even in your country of destination, even if it is not officially registered. 

Quick guide

Complete User Guide

Complete User Guide + Humidifier

More details

37267
New product

1 951,04 €

- +

 
More info

A new beginning in respiratory care.
The solution for the night ventilation aimed at complianti patients suffering from OSA (obstructive sleep apnea).
Equipped with a health care remotely truly integrated system, AirCurve 10 vauto is designed to assist you in managing the most challenging OSA patients. With a sleek new design and improved ease of use, the new AirCurve 10 VAuto stabilizes breathing through the automatic pressure regulation, ensuring a constant pressure support for those who need a greater breathing comfort.

Automatic Bilevel ventilator with AutoSet™ and V-Auto™ algorithm for ventilation mainly in patients suffering from Obstructive Sleep Apnea (OSA) is not compliant with CPAP therapy; Auto CPAP therapy. It equipped with data transmission-reception wireless technology on the GSM network.
Enhanced AutoSet™ algorithm, clinically validated for automatic response to flow limitation, Snoring and Apnea, with distinction of the types of apnea.
Technology "F.O.T."™ (Forced Oscillation Technology) able to distinguish from Central Apnea Obstructive Apnea with improvement of pressor responses and appropriate responses to individual events.
Algorithm V-Auto™ clinically validated for the dispensing of the pressure support with EPAP pressure car settante. V-Sync™ clinically validated algorithm for automatic compensation of the losses and the re-alignment of the ventilation parameters to complete synchronization with the patient. Automatic calculation of intentional leakage of exhalation mask with holes interface selection from the settings menu.
Operating pressures from 4 to 20 cmH2O
It is adapted to all types of vented masks and to all the circuits by 22 mm.
The package includes the device, a circuit and carrying bag.

Functions available in the VAuto model:

  • CPAP function
  • VAuto function
  • S function
  • EasyBreathe™ function
  • Climate Control
  • Climate Control Auto
  • Vsync leak management
  • Integrated wireless connectivity

What is included in the basic package:

  • Device
  • Carrying case
  • Non heated tube
  • Power supply
  • Power cord
  • GSM module
  • User manual
  • SD card holder
  • SD card

What is NOT included, but must be purchased as an accessory:

  • Humidifier
  • Replacement filters
  • Heated tube
  • Clinical manual
  • Alternative solutions for power supply

Features:

  • Operating modes: VAuto - S - CPAP
  • Selection of interfaces: Mask Type
  • Ventilation Type: Non Invasive
  • Supplied pressure: 4 to 20 cmH2O
  • Auto Set Algorithm for the treatment of obstructive events: Flow limitation - snoring - apnea
  • VAuto algorithm
  • Vsync algorithm automatically compensates for unintentional leak and automatic re-alignment of the basement ventilation line
  • Manually adjustable ramp time (CPAP) to achieve the therapeutic pressure
  • Manual adjustment stabilization time (Auto) for the achievement of the therapeutic pressure
  • Automatic altitude compensation
  • High leakage alarm
  • Color LCD display for direct visualization of the following parameters:
  1. Settings
  2. Mode in use
  3. Pressures provided
  4. Pressure Support
  5. Loss in liters/minute
  6. Respiratory rate
  7. Current volume Inspiratory
  8. Inspiratory Minute Volume
  9. Apnea/Hypopnea index
  10. Apnea Index
  11. Efficacy data and usage data
  12. SpO2 and heart rate (with optional module)
  13. Patient menu (basic and advanced)
  14. Options
  • Smart Start™ function pauses/resumes therapy when it detects the disconnection/connection of the mask from the patient's face
  • Reminder programming for the patient at repeated intervals, 1 to 24 months (replacement mask - filter change - call doctor - inserting memory card - Technical call - customizable reminder).
  • Internal memory of 365 sessions that can be viewed on the device, ResScan™ and wirelessly via AirView™ and 30 sessions of detailed data at high resolution can be displayed on the computer through the dedicated ResScan™ software with patient record management, follow-up, programming visits of control, etc.
  • optional integrated heated humidification system and Humid Air™ with Climate Control™ for control (automatic or manual) of temperature and humidification levels. patient circuit optional Climate Lineair™, heated and equipped with temperature sensors for dispensing in automatic 85% relative humidity. An anti-fog protection system, even at very high levels of humidification.
  • 110/220 Volt power supply with the possibility (optional) to use with power supply 12/24 Volt
  • Optional external battery ResMed Power Station II™.
  • Equipment complies with international IEC 601.1, class II type CF, made in compliance with the EU Directive 93/42/EEC (CE).
  • Emission level 27 dBA sound, pressure level at 1 meter 13dBA
  • Size in mm: 116 Height - Width 255 - Depth 150
  • Environmental conditions: operating temperature between +5 and + 40 ° C - Operating humidity 15-95% non-condensing - Storage and transport temperature of -20 to + 60 ° C - Storage and transport humidity up to 95% non-condensing
  • Provided with bag for transportation for equipment and accessories.

Write a review

ResMed - AirCurve 10 VAuto BiLevel

The AUTO BILEVEL AirCurve 10 VAUTO by ResMed is the only Auto BiLevel existing on the market and the only one equipped with the BiLevel AutoRamp™ feature, which allows the device to replace the doctor in therapy control. It is also equipped with a patient's GSM automatic monitoring system, which communicates with the single AirView ResMed™ program to have a perfect check of the patient constantly updated and allows the possibility to send the data of the therapy to the treating physician.

The AutoRamp™ mode with the sleep detection principle is activated automatically providing a low pressure during the step of pre-sleep for greater comfort, gradually increasing the pressure until reaching the prescribed therapy from the time when the patient falls asleep.

The EasyBreathe™ algorithm allows a greater pressure support to easily treat patients with difficult conditions of obstructive sleep apnea, replicating the shape of the patient's breathing curve itself.

When the device is integrated into a humidifier and the heated ClimateLineAir™ circuit becomes able to provide the temperature and the optimum moisture content for the user, so as to obtain the maximum possible comfort by therapy. 

Caution: the package does NOT include the humidifier. 

The product is registered in Italy.