Air Outlet for AirSense 10 and AirCurve 10 - ResMed

The Humidifier Chamber Air Outlet for ResMed AirSense™ 10 and AirCurve™ 10 Series CPAP and BiLevel Machines is the replacement air outlet elbow for the AirSense 10 and AirCurve 10 line of CPAP and bilevel machines when the existing outlet has been damaged.

This air outlet is available in one color only. It is for use with the following machines:

  • AirSense™ 10 AutoSet CPAP Machine with HumidAir™ Heated Humidifier
  • AirSense™ 10 Elite CPAP Machine with HumidAir™ Heated Humidifier
  • AirSense™ 10 CPAP Machine with HumidAir™ Heated Humidifier
  • AirSense™ 10 AutoSet For Her CPAP Machine with HumidAir™ Heated Humidifier
  • AirCurve™ 10 S BiLevel Machine with HumidAir™ Heated Humidifier
  • AirCurve™ 10 VAuto BiLevel Machine with HumidAir™ Heated Humidifier

More details

202410300250
New product
 
More info

The Humidifier Chamber Air Outlet for ResMed AirSense™ 10 and AirCurve™ 10 Series CPAP and BiLevel Machines is the replacement air outlet elbow for the AirSense 10 and AirCurve 10 line of CPAP and bilevel machines when the existing outlet has been damaged.

This air outlet is available in one color only. It is for use with the following machines:

  • AirSense™ 10 AutoSet CPAP Machine with HumidAir™ Heated Humidifier
  • AirSense™ 10 Elite CPAP Machine with HumidAir™ Heated Humidifier
  • AirSense™ 10 CPAP Machine with HumidAir™ Heated Humidifier
  • AirSense™ 10 AutoSet For Her CPAP Machine with HumidAir™ Heated Humidifier
  • AirCurve™ 10 S BiLevel Machine with HumidAir™ Heated Humidifier
  • AirCurve™ 10 VAuto BiLevel Machine with HumidAir™ Heated Humidifier

Instructions for Replacing the Air Outlet

  1. Remove the HumidAir humidifier chamber from the machine body.
  2. Locate the ring around the air outlet port on the back of the machine.
  3. Rotate the ring until the two orange marks are positioned above / below the air outlet port.
  4. Insert an index finger into the air outlet port from the outside of the machine.
  5. Looking into the opening on the side of the machine vacated by the humidifier chamber, locate the rounded release tab on the interior portion of the outlet.
  6. With your other index finger, depress the release tab visible below the air outlet gasket.
  7. While depressing the small tab, use the inserted finger to pull out on the outlet.
  8. NOTE: The tab may be stiff and require a fair amount of pressure to get it to release.
  9. After removing the old air outlet, insert the replacement air outlet from the outside of the machine into the opening.
  10. Ensure the tab of the air outlet is securely in place on the inside of the machine.
  11. Rotate the ring on the back of the machine to lock the air outlet port.
  12. The ring is locked when the orange marks are left / right of the air outlet port.
  13. Reinstall the humidifier chamber.

Write a review

Air Outlet for AirSense 10 and AirCurve 10 - ResMed

The Humidifier Chamber Air Outlet for ResMed AirSense™ 10 and AirCurve™ 10 Series CPAP and BiLevel Machines is the replacement air outlet elbow for the AirSense 10 and AirCurve 10 line of CPAP and bilevel machines when the existing outlet has been damaged.

This air outlet is available in one color only. It is for use with the following machines:

  • AirSense™ 10 AutoSet CPAP Machine with HumidAir™ Heated Humidifier
  • AirSense™ 10 Elite CPAP Machine with HumidAir™ Heated Humidifier
  • AirSense™ 10 CPAP Machine with HumidAir™ Heated Humidifier
  • AirSense™ 10 AutoSet For Her CPAP Machine with HumidAir™ Heated Humidifier
  • AirCurve™ 10 S BiLevel Machine with HumidAir™ Heated Humidifier
  • AirCurve™ 10 VAuto BiLevel Machine with HumidAir™ Heated Humidifier

Write a review

15 other products in the same category: