High Flow nasal cannula Salter Labs - 7 ft

The Salter 16 SOFT HF Cannula virtually eliminates flow noise. These cannulas includes a 7-foot crush and kink-resistant supply tube.

Salter 16 SOFT HF Cannulas are designed for oxygen flows up to 15 LPM.

This cannula is recommended for High Flow concentrators. 

More details

101311300090
New product
 
More info

The Salter 16 SOFT HF Cannula virtually eliminates flow noise. These cannulas includes a 7-foot crush and kink-resistant supply tube.

Salter 16 SOFT HF Cannulas are designed for oxygen flows up to 15 LPM.

This cannula is recommended for High Flow concentrators.

The clear and light cannula Salter 16 SOFT High Flow incorporates a piece anatomically designed sole that eliminates the need for irritating joints. The supply tube 7 feet (approximately 2.1 m) includes a three-channel design, resistant to crushing and deformation; while the set "over-the-ear" is placed around the head ensures secure positioning, allowing greater freedom of movement, regardless of movements and loss of oxygen.

USE: The cannula Salter 16 SOFT HF is suitable for flows up to 15 LPM.

Medical device.

Manufactured by: SALTER LABS 100 W. Sycamore Road Arvin USA

C.E. certification: n° organism 0123

Class of membership in accordance with the European Directive 93/42/EEC: IIa

Latex presence: NO

Sterile device: NO

Made of soft PVC medical non-toxic 

Tecnical specification:

  • Single patient
  • Transparent
  • Anatomical shape
  • Tube with internal star section anti occlusion

Quality control:
All products Salter Labs are assembled in a workshop certified by the Ministry of Health.
All products are tested at 100%.

Tolerability:
The product finds no incompatibility to the substances with which it comes into contact during normal use.

Contraindications and precautions:
From the point of view of the chemical and physical stability of the product and the material which it is made does not undergo any alterations in time. Exposure to sunlight or artificial sources of light will not change the structure of the product, provided the integrity of the pack.

Storage:
Store in a dry place away from heat.
Storage temperature: 0 ° C / + 60 ° C

Product disposal:
When the device is removed to take adequate precautions.
Dispose of it according to the laws and regulations applicable to hospital biohazard waste.

Write a review

High Flow nasal cannula Salter Labs - 7 ft

The Salter 16 SOFT HF Cannula virtually eliminates flow noise. These cannulas includes a 7-foot crush and kink-resistant supply tube.

Salter 16 SOFT HF Cannulas are designed for oxygen flows up to 15 LPM.

This cannula is recommended for High Flow concentrators. 

Write a review

18 other products in the same category: